Descriptor English: | Electroporation | ||||||
Descriptor Spanish: |
Electroporación
| ||||||
Descriptor Portuguese: | Eletroporação | ||||||
Descriptor French: | Électroporation | ||||||
Entry term(s): |
Electric Field-Mediated Cell Permeabilization Electropermeabilisation Electroporation, Irreversible Electroporation, Reversible Irreversible Electroporation Reversible Electroporation |
||||||
Tree number(s): |
E05.200.500.454 E05.242.448 E05.301.500 |
||||||
RDF Unique Identifier: | https://id.nlm.nih.gov/mesh/D018274 | ||||||
Scope note: | A technique in which electric pulses, in kilovolts per centimeter and of microsecond-to-millisecond duration, cause a loss of the semipermeability of CELL MEMBRANES, thus leading to ion leakage, escape of metabolites, and increased uptake by cells of drugs, molecular probes, and DNA. Depending on the dosage, the formation of openings in the cell membranes caused by the electric pulses may or may not be reversible. |
||||||
Allowable Qualifiers: |
CL classification EC economics ES ethics HI history IS instrumentation MT methods SN statistics & numerical data ST standards TD trends VE veterinary |
||||||
Public MeSH Note: | 94 |
||||||
History Note: | 94 |
||||||
DeCS ID: | 31491 | ||||||
Unique ID: | D018274 | ||||||
Documents indexed in the Virtual Health Library (VHL): | Click here to access the VHL documents | ||||||
Date Established: | 1994/01/01 | ||||||
Date of Entry: | 1993/06/03 | ||||||
Revision Date: | 2022/04/08 |
-
-
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT
Investigative Techniques [E05]Investigative Techniques -
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT
Investigative Techniques [E05]Investigative Techniques -
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT
Investigative Techniques [E05]Investigative Techniques
|
Electroporation
- Preferred
Irreversible Electroporation
- Narrower
Reversible Electroporation
- Narrower
Concept UI |
M0027505 |
Scope note | A technique in which electric pulses, in kilovolts per centimeter and of microsecond-to-millisecond duration, cause a loss of the semipermeability of CELL MEMBRANES, thus leading to ion leakage, escape of metabolites, and increased uptake by cells of drugs, molecular probes, and DNA. Depending on the dosage, the formation of openings in the cell membranes caused by the electric pulses may or may not be reversible. |
Preferred term | Electroporation |
Entry term(s) |
Electric Field-Mediated Cell Permeabilization Electropermeabilisation |
Concept UI |
M000752590 |
Scope note | Cell permeabilization induced by higher intensity voltages that cause irreparable cell membrane openings which triggers APOPTOSIS. |
Preferred term | Irreversible Electroporation |
Entry term(s) |
Electroporation, Irreversible |
Concept UI |
M000752591 |
Scope note | Application of electric pulses to cells in doses that cause only temporary permeabilization of CELL MEMBRANES. |
Preferred term | Reversible Electroporation |
Entry term(s) |
Electroporation, Reversible |
We want your feedback on the new DeCS / MeSH website
We invite you to complete a survey that will take no more than 3 minutes.
Go to survey