Descriptor English: | Voltage-Sensitive Dye Imaging | ||||
Descriptor Spanish: |
Imagen de Colorante Sensible al Voltaje
| ||||
Descriptor Portuguese: | Imagens com Corantes Sensíveis à Voltagem | ||||
Descriptor French: | Imagerie par colorant sensible au potentiel | ||||
Entry term(s): |
Action Potential Optical Mapping Anatomic Electrical Activity Optical Mapping Imaging, Voltage-Sensitive Dye Mapping, Optical Vm Mappings, Optical Vm Optical Action Potential Mapping Optical Mapping, Action Potential Optical Mapping, Anatomic Electrical Activity Optical Mapping, Transmembrane Potential Optical Transmembrane Potential Mapping Optical Vm Mapping Optical Vm Mappings Transmembrane Potential Optical Mapping Vm Mapping, Optical Vm Mappings, Optical Voltage Sensitive Dye Imaging |
||||
Tree number(s): |
E01.370.350.887 |
||||
RDF Unique Identifier: | https://id.nlm.nih.gov/mesh/D056969 | ||||
Scope note: | Optical imaging techniques used for recording patterns of electrical activity in tissues by monitoring transmembrane potentials via FLUORESCENCE imaging with voltage-sensitive fluorescent dyes. |
||||
Allowable Qualifiers: |
AE adverse effects CL classification EC economics ES ethics HI history IS instrumentation MO mortality MT methods NU nursing PX psychology SN statistics & numerical data ST standards TD trends VE veterinary |
||||
Public MeSH Note: | 2010 |
||||
History Note: | 2010 |
||||
DeCS ID: | 53676 | ||||
Unique ID: | D056969 | ||||
Documents indexed in the Virtual Health Library (VHL): | Click here to access the VHL documents | ||||
Date Established: | 2010/01/01 | ||||
Date of Entry: | 2009/07/06 |
-
-
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT
Diagnosis [E01]Diagnosis
|
Voltage-Sensitive Dye Imaging
- Preferred
Optical Action Potential Mapping
- Narrower
Concept UI |
M0533638 |
Scope note | Optical imaging techniques used for recording patterns of electrical activity in tissues by monitoring transmembrane potentials via FLUORESCENCE imaging with voltage-sensitive fluorescent dyes. |
Preferred term | Voltage-Sensitive Dye Imaging |
Entry term(s) |
Imaging, Voltage-Sensitive Dye Mapping, Optical Vm Mappings, Optical Vm Optical Mapping, Transmembrane Potential Optical Transmembrane Potential Mapping Optical Vm Mapping Optical Vm Mappings Transmembrane Potential Optical Mapping Vm Mapping, Optical Vm Mappings, Optical Voltage Sensitive Dye Imaging |
Concept UI |
M0533639 |
Preferred term | Optical Action Potential Mapping |
Entry term(s) |
Action Potential Optical Mapping Anatomic Electrical Activity Optical Mapping Optical Mapping, Action Potential Optical Mapping, Anatomic Electrical Activity |