Descriptor English: | Intra-Aortic Balloon Pumping | ||||||
Descriptor Spanish: |
Contrapulsador Intraaórtico
| ||||||
Descriptor Portuguese: | Balão Intra-Aórtico | ||||||
Descriptor French: | Contrepulsion par ballon intra-aortique | ||||||
Entry term(s): |
Balloon Pumping, Intra-Aortic Balloon Pumping, Intraaortic Intra Aortic Balloon Pumping Intraaortic Balloon Pumping Pumping, Intra Aortic Balloon Pumping, Intra-Aortic Balloon Pumping, Intraaortic Balloon |
||||||
Tree number(s): |
E04.050.215.400 |
||||||
RDF Unique Identifier: | https://id.nlm.nih.gov/mesh/D007423 | ||||||
Scope note: | Counterpulsation in which a pumping unit synchronized with the patient's electrocardiogram rapidly fills a balloon in the aorta with helium or carbon dioxide in early diastole and evacuates the balloon at the onset of systole. As the balloon inflates, it raises aortic diastolic pressure, and as it deflates, it lowers aortic systolic pressure. The result is a decrease in left ventricular work and increased myocardial and peripheral perfusion. |
||||||
Allowable Qualifiers: |
AE adverse effects CL classification EC economics ED education ES ethics HI history IS instrumentation LJ legislation & jurisprudence MO mortality MT methods NU nursing PX psychology RH rehabilitation SN statistics & numerical data ST standards TD trends VE veterinary |
||||||
Previous Indexing: |
Assisted Circulation (1967-1976) |
||||||
Public MeSH Note: | 86; was see under ASSISTED CIRCULATION 1977-85 |
||||||
History Note: | 86(77); was see under ASSISTED CIRCULATION 1977-85 |
||||||
Entry Version: | IABP |
||||||
DeCS ID: | 7586 | ||||||
Unique ID: | D007423 | ||||||
NLM Classification: | WG 168 | ||||||
Documents indexed in the Virtual Health Library (VHL): | Click here to access the VHL documents | ||||||
Date Established: | 1986/01/01 | ||||||
Date of Entry: | 1976/04/13 | ||||||
Revision Date: | 1994/01/25 |
-
-
ANALYTICAL, DIAGNOSTIC AND THERAPEUTIC TECHNIQUES, AND EQUIPMENT
Surgical Procedures, Operative [E04]Surgical Procedures, Operative
|
Intra-Aortic Balloon Pumping
- Preferred
Concept UI |
M0011587 |
Scope note | Counterpulsation in which a pumping unit synchronized with the patient's electrocardiogram rapidly fills a balloon in the aorta with helium or carbon dioxide in early diastole and evacuates the balloon at the onset of systole. As the balloon inflates, it raises aortic diastolic pressure, and as it deflates, it lowers aortic systolic pressure. The result is a decrease in left ventricular work and increased myocardial and peripheral perfusion. |
Preferred term | Intra-Aortic Balloon Pumping |
Entry term(s) |
Balloon Pumping, Intra-Aortic Balloon Pumping, Intraaortic Intra Aortic Balloon Pumping Intraaortic Balloon Pumping Pumping, Intra Aortic Balloon Pumping, Intra-Aortic Balloon Pumping, Intraaortic Balloon |
We want your feedback on the new DeCS / MeSH website
We invite you to complete a survey that will take no more than 3 minutes.
Go to survey